Still deciding? Get samples of $ !
Request Sample
|
| After-sales Service: | Repair, Replace, Refund |
|---|---|
| Warranty: | 3-Year |
| Type: | Right-Angle Prism |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Name: | Optical Right-Angle Prisms |
Substrates: | Optical Glass, Infrared Glass, UV Fused Silica, N-BK7, N-SF11, Sapphire, CaF2, ZnSe, etc... |
Dimensional Tolerance: | +/-0.1mm, as required |
Usable Aperture: | >90% Dimensions |
Optical Quality: | Commercial Grade |
Surface Quality: | 40-20 or better (Per MIL-PRF-13830B) |
Wavefront Distortion:: | 1/[email protected] or better |
Angle Tolerance: | +/-15arcsec |
Coatings: | Uncoated, AR Coatings, Dielectric Coatings, Metallic Coatings, etc... |
Bevels: | Break all sharp edges |
Chamfer: | <0.25mmx45° |
Damage Threshold: | Aluminum hypotenuse: 100 W/cm2 CW, 10 mJ/cm2 with 10 nsec pulses, typical |
Mechanical: | Unmounted or Mounted |
Question | Key Decision Points / Root Causes | Typical Loss / Spec | Practical Fix / Enhancement | Where it’s Used |
TIR vs. Mirrored – which one do I pick? | • Incident angle > critical angle (e.g. 41° for BK7 in VIS) → TIR • Need durability (no coating to age) → TIR • Working visible band → TIR • Angle < critical or UV/IR bands (Ge 17°) or need R > 98 % in low light → mirror | TIR: R ≈ 100 % (theory) Mirrored: R 95-99 % depending on coating | TIR: keep prism clean, use collimated beam Mirrored: choose Al+MgF2 (UV) or Au/Ag (IR) coating | TIR: camera viewfinders, lab spectrometers Mirrored: night-vision, IR thermal imagers, UV-cure lasers |
Reflection loss in TIR mode? | 1. Surface contamination changes n at hypotenuse → local angle drops below θc 2. Off-axis rays enter at θ < θc → light leaks through | < 0.1 % ideal < 5 % if dirty < 1 % if beam has divergence | • Clean with lens tissue + IPA • Collimate beam or use larger prism to widen angular acceptance • AR-coat entrance/exit faces only | High-power laser steering, interferometry |
Can a right-angle prism act as a retroreflector? | Yes, if beam is collimated and enters one leg, double TIR on hypotenuse & opposite leg, exits parallel but offset 180° | Return beam offset = 2 × leg length | Polish all faces λ/10 to keep wavefront error < λ/4 | Laser rangefinders, survey corner-cube substitutes, road-studs |